withlight

  • HOME
  • KOREAN
  • bullettitle

    • opi-150
    • Specifications
      Peak / Dominant Wavelength p, d Refer to LEOS(OPI-100) :
      Providing with all the items/specifications to measure In LEOS
      Luminous / Radiant Intensity IV, Ie
      CIE Color Coordinates Cx, Cy
      Half With Hw
      Reverse Current / Voltage Ir, Vr
      Forward Current / Voltage If, Vf
      *Luminous / Radiant Flux v, e
      CCT(Tc),CRI(Ra),Optical Efficacy(K)
      Light-Current-Voltage Sweep
      Power source Max 1~10A, Pulse mode support (Optional)
      Spectrum ranage UV, UV~Visible, Visible, Visible~IR, IR, UV~IR ( Selectable )
      Optical Power 0.0001 ~ 100 cd (Selectable)
      Rank Max 256Bin
      Interface Parallel/RS-232C/GPIB(Optional)
      Data-storage format Excel(*, CSV )/Text/Image(BMP)
      Built-in PC Windows XP, Pentium M 1.6G Hz , RAM 512 MB, HDD 80G, 17 LCD Monitor
      Power 100~230 VAC, 50/60 Hz
      Available Temperature /Moisture 5~40/Less than 95% relative, non-condensing
    • with probe system
    • پ ׸ ϰ , User Interface(ֹ Ʈ  )
    • All electrical / optical characteristics measured by tester(LEOS), sweep measurement
    • Optical Measurement
    •   Spectrum, Peak/Dominant wave length (p, d), CIE Color Coordinate(Cx,Cy Color Coordinates),
    •   Luminous Intensity(IV,Light Intensity), Correlated Color Temperature(CCT(Tc), Correlated Color Temperature),
    •   Color Rendering Index(CRI(Ra), color rendering), CIE XYZ ( tristimulus values), POL (polarity)
    • Electrical Measurement
    •   Forward /Reverse Current (If, Ir), Forward/Reverse Voltage (Vf,Vr), I-V-L Sweep
    • Detecting edge by software
    • Ink marking
    • Rapid measurement speed : 0.3 sec / sample ( Automatic)
    • Modification storing and editing of measurement conditions
    • Simple and convenient station operation, wafer alignment
    • Ranking and mapping for measurement data based on user grade
    • Statistical Processing and storing (Graph, Mapping, Excel(*,CSV). Text, BMP) simultaneously
    • Compatibility of measured data (data compatibility with general sorer)
    • Optimized user interface environment for mass production, quality management and R&D
    •  پ ȣȯ
    • TTL, Rs232, GPIB Interface (TTL : 8 inputs, 10 outputs(photo coupler)
    • Setting Active mode for input and output ports
    • Additional current supply for polarity measurement: 0~10mA, Additional current supply for optical spectrum measurement: 0~1A
    • Ȯϰ ŷڼ ִ
    • CIE measurement mode and Applying standard value of Korea Research Institute of Standards and Science retroactively
    • High precision measurement using Keithley 2400
    • Low noise, high precision and high repetitiveness by TE Cooled 2048 pixel CCD sensor