OPI-810  THERMAL LEOS

Thermal LEOS is able to measure MULTI CHANNEL LEOSÀÇoptical and electrical property of MULTI CHANNEL LEOS as well as thermal property. It allows measurement of temperature and thermal resistance of PN connection part by analyzing physical property of high


  • Key features
  • ¤ýMeasurement of temperature and thermal resistance of PN connection part by analyzing physical property of high power LED.

  • ¤ýMeasure thermal property of LED (Temperature and thermal resistance of connection part) in normal and excessive status.

  • ¤ýObtain beneficial information for package design by analyzing functional process of high power LED and figuring out thermal flow.

  • ¤ýSimultaneous measurement of optical properties and electrical property of LED to ambient temperature.

  • ¤ýApplied to securing LED efficacy and stable temperature persistency in accordance with change of temperature in connection part.

  • ¤ýSuitable for related R&D and QRA.

  • Measuring targets
  •  
  •  
  •  
  • ¤ýHeat sink type SMD LEDs, Metal PCB type LEDs, Multi chip LEDs of SMD type
  •  
  •  k-factor measurement, temperature rising measurement, Structure function
  •  
  •  
  • Verification of Structure Function
  •  
  • recorded function, derived response function, reconstructed timie-constant spectrum R-thermal
  • differential structure function